Navitron Systems Ltd |
NT990BNWAS
Technical Specifications |
|
Certification
Standards: -
|
|
BSH (Germany) & Germanischer Lloyd type tested and Approved to MSC.128(75)
|
|
BNWAS
Input / Output Specifications
|
|
Inputs:
- |
Outputs: - |
|||||||||
Type |
Supply Voltage |
Power |
Alarm Outputs & Status Displays |
|||||||
|
BNWAS / 1 |
Primary 24Vdc (18-36Vdc) |
2.5W to 3.8W (max illum) + 1W per Remote Reset |
Bridge Visual (15 secs) |
LED + volt free N/O contact rated 5A @ 30Vdc/220VAC |
  | |||||
Emerg 24Vdc (18-36Vdc) |
||||||||||
|
BNWAS / 2
|
115/230VAC 50/60Hz Backup 24Vdc (18-36Vdc) Emerg 24Vdc (18-36Vdc) |
|||||||||
Bridge Audible (15 secs) |
LED + volt free N/O contact rated 5A @ 30Vdc/220VAC |
Tone & Volume installation adjustable |
||||||||
Auto (Remote) Activation |
||||||||||
|
Two Opto isolated input types: - |
Officer Call (90 - 180 secs) |
LED + volt free N/O contact rated 5A @ 30Vdc/220VAC |
90, 120, 150, 180 secs installation adjustable |
|||||||
NMEA sentence $XXHTD |
Installation selectable for 4800 or 38,400 baud |
|||||||||
|
Analogue Voltage
11-40Vdc |
Installation selectable switchline polarity |
|||||||||
Crew Call (Until Reset) |
LED + volt free N/O contact rated 5A @ 30Vdc/220VAC |
Can be combined with Officer Call |
||||||||
|
|
||||||||||
|
Operator Controls
|
||||||||||
Time |
3 to 12 minutes selectable in 1 min increments |
Keyswitch security protected |
||||||||
AC Power Fail (BNWAS 2) |
Status LED |
Volt free N/O contact rated 5A @ 30Vdc/220 VAC for ext. console malfunction alarm |
||||||||
Work Mode |
Selectable 'ON', 'OFF' or 'AUTO' Mode |
DC Power Fail |
Status LED |
|||||||
Illum |
Variable Red LED Backlight |
Keypad |
Computer Fail |
Status LED |
||||||
Reset |
Cancels all alarms and resets timing cycles
|
Pushbutton |
||||||||
Tamper |
Status LED |
|||||||||
Complete Power Fail |
Volt free S/P C/O contact |
To external Fail Alarm |
||||||||
Emergency Call |
Summons immediate Officer assistance |
Protected pushbutton |
||||||||
Reset (Remote Unit) |
Cancels alarms / Restarts timing / Adjusts Remote unit illumination level |
Pushbutton |
||||||||
Operating Temperature Range |
||||||||||
-15 to +55°C |
||||||||||
|
|
||||||||||
Mechanical |
||||||||||
Weight |
Compass Safe Distance (CSD) |
|||||||||
1.0Kg |
0.2m |
|||||||||
0.85Kg |
0.2m |
|||||||||
1.5Kg |
0.2m |
|||||||||
0.2Kg |
0.2m |
|||||||||
0.15Kg |
0.1m |
|||||||||
0.5Kg |
0.1m |
|||||||||
0.5Kg |
0.1m |
|||||||||
3.1Kg |
0.25m |
|||||||||
0.25Kg |
0.1m |
|||||||||
0.75Kg |
0.1m |
|||||||||
| |
|
|